ASTM D543 PDF

ASTM D CHEMICAL RESISTANCE. These practices cover the evaluation of all plastic materials including cast, hot-molded, cold-molded, laminated. Buy ASTM D PRACTICES FOR EVALUATING THE RESISTANCE OF PLASTICS TO CHEMICAL REAGENTS from SAI Global. ASTM D , Standard Practices for Evaluating the Resistance of Plastics to ASTM D , Standard Test Method for Abrasion Resistance of Organic.

Author: Mocage Mogal
Country: Iceland
Language: English (Spanish)
Genre: Medical
Published (Last): 5 February 2011
Pages: 192
PDF File Size: 20.66 Mb
ePub File Size: 8.10 Mb
ISBN: 991-2-30910-442-8
Downloads: 83850
Price: Free* [*Free Regsitration Required]
Uploader: Mazunos

This standard does not purport to address all of the safety concerns, if any, associated with its use. Assurance Testing Inspection Certification. This slight angle is a characteristic of the JetCut process.

Need help or have a question?

Auditing Consulting Sourcing Training. Depending upon the type of asfm anticipated for the test sample, the exposure to the chemical agent could be immersion, wipe, spray, or saturated gauze. The low flexural yield stress results from Plates 11 and 12 could be due to the greater test specimen depth or inherent flaws in the test coupons Figure 5.

Test results were compared with the water control of the immersed tests. Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard. BOD coupons were taken from Plates 12 and Active view current version of standard. Five percent Ammonium Hydroxide showed the greatest change 3.

Inspection Validating the specifications, value and safety of your raw materials, products and assets. Chemical reagents can include lubricants, cleaning agents, inks, foods, or anything else that the test material may be expected to come in contact with.

  HIGHLAND SCOUNDREL MONICA MCCARTY PDF

ASTM D – CHEMICAL RESISTANCE

Posted by Tabitha at 8: The test includes provisions for reporting changes in weight, dimensions, appearance and strength properties. Through our network of over 43, people in 1, laboratories and offices in countries, Intertek provides quality and safety solutions to a wide range of industries around the world. Visual examination of a non-tested coupons cut from Plate 12 revealed that the coupon had an inherent plane of weakness in the middle of the test awtm Figure 5.

This slight angle resulted in laminate coupons being moderately wider on one face top compared to bottom.

Chemical Compatibility ASTM D543

The test samples are then sealed in a container, and either left at room temperature or placed in an oven. All chemical reagents appear to decrease the laminates flexural yield stress and yield strain. Note 1 This standard and ISO Part 3 address the same subject matter, but differ in technical content and the results cannot be directly compared between the two test methods.

The type of conditioning immersion or wet patch depends upon the end-use of the material. Variations in test coupon depth indicate that these test plates had greater variation in depth across the plate than the other test plates.

The most typical physical strength properties evaluated are tensile strength and elongation.

Evaluating how dd543 products and services meet and exceed quality, safety, sustainability and performance standards. For applications involving continuous immersion, the data obtained in short-time tests are of interest only in eliminating the most unsuitable materials or indicating a probable relative order of resistance r543 chemical reagents. Link to Active This link will always route to the current Active version of the standard.

  ENFERMEDAD DE MARCHIAFAVA BIGNAMI PDF

These practices include provisions for reporting changes in weight, dimensions, appearance, and strength properties.

ASTM D – 06 Standard Practices for Evaluating the Resistance of Plastics to Chemical Reagents

Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard. It should also be noted that two of the coupons 1 lb and c show much higher stress-strain response than a. Based on Figure 5.

Specimens can be weighed and measured prior to contact with the chemical reagent. While measuring the laminate coupons it was noted that the specimen edges were at a slight angle with respect to the depth of the material. All test laminate coupons measured approximately mm in length by 25 mm in width and 5 mm in depth.

Further testing is required to confirm whether 0. This test covers the evaluation of plastic materials for resistance to chemical reagents, simulating performance in potential end use environments. Further testing is required to determine if 0. Send us a request Wilton UK: It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

The strain fixtures and laminate coupons were placed in Plastic containers filled with chemical reagent. All weight and dimension changes were less than 0.